ISOVER

PRODUCTS ISOVER

ISOVER HygroWick® 

ISOVER HygroWick® are coiled pipe insulation sleeves made of glass wool. The insulating sleeve has the shape of a hollow longitudinally divided cylinder made of one segment. ISOVER HygroWick® is provided on the inside with a non-flammable capillary conductive fabric to ensure functionality in insulating cold distribution and on the outside it is provided with a surface treatment with aluminum foil. The longitudinal joints are glued with system perforated aluminum tape to perfectly close the housing and to create a functional and aesthetic covering of the capillary conductive fabric.

APLICATION

Insulating sleeve suitable for cold or dual distribution in the temperature range 0 to 250 ° C, especially for cases where there is also a requirement for non-flammability of insulation (protected escape routes, etc.). The insulation thickness must be at least such that the surface temperature of the cladding is higher than the dew point temperature.

ADVANTAGES

  • non-flammable type of insulation – reaction to fire class A2L-s1,d0
  • very good thermal insulation performance
  • excellent workability – the product can be easily cut with a sharp knife
  • very fast installation – without the need to glue the joints with adhesive
  • constant thermal conductivity over time thanks to the active element (capillary conductive fabric)
  • the only type of insulation that can be applied to pipes in operation
  • the product is made of min. 70% recycled glass

Technical Specifications

CharacteristicUnitValuesStandard
THERMAL PROPERTIES
The declared value of the coefficient of thermal conductivity according to ČSN EN ISO 13787**°C1050100150
W·m-1·K-10,0330,0360,0430,051
Highest operating temperature ST (+) / on the aliminium foil side°C150 / max. 80ČSN EN 14707
PHYSICAL PROPERTIES
Density *kg·m-375ČSN EN 1602, ČSN EN 13470
ANTI-FIRE PROPERTIES
Insulating case with aluminum coating: Reaction to fire - additional classification for smoke generation, flaming particlesA2L-s1, d0ČSN EN 13501-1

* Informative undeclared value beyond CPR, obtained by specific tests.
** Measured based on the methodology defined by ČSN EN ISO 8497.

Thermal conductivity coefficient for 0 °C: λ0 = 0.032 W·m-1·K-1. The value is used to compare products according to Decree 193/2007 Coll. – according to § 5, paragraph 8 (for thermal insulation of distribution systems).

ISOVER HygroWick® documents download (PDF)

ACCESSORIES ISOVER HygroWick®

Perforated aluminum tape

The longitudinal joints are glued with system perforated aluminum tape to perfectly close the housing and to create a functional and aesthetic covering of the capillary conductive fabric.

Technical Specifications

ISOVER HygroWick® ALU tape perforated
Width100 mm
Lenght50 mm

Capillary conductive fabric

Elbows, flanges, valves and other fittings are wrapped with capillary conductive fabric to create a continuous capillary path with the adjacent insulation sleeve fabric.

Technical Specifications

ISOVER HygroWick® fabric
Width80 mm1200 mm
Lenght50 mm50 mm

Price list ISOVER HygroWick®